{"id":3081,"date":"2026-10-03T20:25:51","date_gmt":"2026-10-03T20:25:51","guid":{"rendered":"https:\/\/nhdbio.com\/?p=3081"},"modified":"2026-10-03T20:25:51","modified_gmt":"2026-10-03T20:25:51","slug":"exemple-simple-de-lcms-de-peptide-avec-etat-de-charge-m-z","status":"publish","type":"post","link":"https:\/\/nhdbio.com\/fr\/peptide-lcms-charge-state-mz-simple-example\/","title":{"rendered":"Pourquoi un spectre de masse peptidique montre-t-il la moiti\u00e9 de la masse attendue ?"},"content":{"rendered":"<p>Votre document sur le peptide indique une masse mol\u00e9culaire proche de 2,000 Da, mais le spectre pr\u00e9sente un pic proche de 1,001. Le fournisseur a-t-il envoy\u00e9 le mauvais mat\u00e9riel ? Ce nombre seul ne permet pas de r\u00e9pondre \u00e0 la question. Un spectrom\u00e8tre de masse mesure la masse divis\u00e9e par la charge, g\u00e9n\u00e9ralement not\u00e9e m\/z.<\/p>\n<h2>Une mol\u00e9cule peut porter plus d'une charge<\/h2>\n<p>Think of the instrument\u2019s number as a divided value. In positive electrospray, a peptide can pick up more than one proton. Two charges divide the ion\u2019s mass by two; three divide it by three. Thermo Fisher\u2019s introduction explains why mass spectrometry reports mass-to-charge values rather than a simple weight.<\/p>\n<h2>Un exemple concret : 2,000 Da devient environ 1,001 m\/z<\/h2>\n<p>Take an imaginary peptide with a neutral mass of 2,000 Da. For proton-only positive ions, use m\/z = (M + z \u00d7 1.0073) \u00f7 z, where M is neutral mass and z is charge. The approximate proton mass is 1.0073 Da. At charge +1, the result is 2,001.0073; at +2, it is 1,001.0073; at +3, it is 667.6739.<\/p>\n<p>Ce sont des valeurs p\u00e9dagogiques calcul\u00e9es, et non des r\u00e9sultats de test NHD. Elles d\u00e9crivent trois \u00e9tats de charge de la m\u00eame mol\u00e9cule hypoth\u00e9tique. Le nombre plus petit ne signifie pas que la cha\u00eene peptidique s'est cass\u00e9e en deux.<\/p>\n<h2>Demandez quel nombre le rapport affiche<\/h2>\n<p>V\u00e9rifiez l'attribution des charges et si le rapport fournit des m\/z brutes ou une masse neutre reconstruite. Demandez aussi s'il utilise la masse monoisotopique ou la masse moyenne. Ce sont diff\u00e9rentes fa\u00e7ons de r\u00e9sumer les isotopes. Les adduits de sodium, d'autres formes ioniques et les fragments n\u00e9cessitent une interpr\u00e9tation diff\u00e9rente ; la simple formule avec protons seuls ne les couvre pas.<\/p>\n<h2>Une concordance de masse est utile, mais ce n'est pas l'int\u00e9gralit\u00e9 du contr\u00f4le qualit\u00e9<\/h2>\n<p>Une masse concordante soutient l'identit\u00e9 propos\u00e9e. Elle ne prouve pas, \u00e0 elle seule, l'ordre de la s\u00e9quence, la puret\u00e9 ou la quantit\u00e9 de peptide dans la poudre. Utilisez le r\u00e9sultat de masse avec les enregistrements analytiques convenus. Notre <a href=\"https:\/\/nhdbio.com\/fr\/methodes-danalyse\/test-didentite-lc-ms\/\">Guide d'identification par LC-MS<\/a> explique cette distinction.<\/p>\n<p>Acheter un mat\u00e9riel de catalogue tel que <a href=\"https:\/\/nhdbio.com\/fr\/produits\/ll-37\/\">LL-37<\/a>, ou demander une s\u00e9quence personnalis\u00e9e ? <a href=\"https:\/\/nhdbio.com\/fr\/citation\/\">Envoyez \u00e0 NHD le mat\u00e9riel exact et demandez quels enregistrements d'identit\u00e9 sont disponibles<\/a>. Confirm the scope before ordering; this example does not establish any supplied lot\u2019s identity.<\/p>\n<p>Pour la recherche en laboratoire uniquement. Non destin\u00e9 \u00e0 un usage humain ou v\u00e9t\u00e9rinaire.<\/p>\n<h2>R\u00e9f\u00e9rences<\/h2>\n<ul>\n<li><a href=\"https:\/\/www.thermofisher.com\/pl\/en\/home\/life-science\/protein-biology\/protein-biology-learning-center\/protein-biology-resource-library\/pierce-protein-methods\/overview-mass-spectrometry.html\">Thermo Fisher : Aper\u00e7u de la spectrom\u00e9trie de masse<\/a><\/li>\n<li><a href=\"https:\/\/assets.thermofisher.com\/TFS-Assets\/CMD\/posters\/po-80036-asms22-charge-assignment-of-isotopically-po80036-en.pdf\">Thermo Fisher : Attribution des charges des donn\u00e9es de masse \u00e0 r\u00e9solution isotopique<\/a><\/li>\n<\/ul>","protected":false},"excerpt":{"rendered":"<p>Votre document sur le peptide indique une masse mol\u00e9culaire proche de 2,000 Da, mais le spectre pr\u00e9sente un pic proche de 1,001. Le fournisseur a-t-il envoy\u00e9 le mauvais mat\u00e9riel ? Ce nombre seul ne permet pas de r\u00e9pondre \u00e0 la question. Un spectrom\u00e8tre de masse mesure la masse divis\u00e9e par la charge, g\u00e9n\u00e9ralement not\u00e9e m\/z.<\/p>","protected":false},"author":1,"featured_media":3083,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"pim_family_ids":"","pim_article_type":"Peptide buying and basics","pim_evidence_level":"Technical references and labeled calculations","pim_reviewer":"Codex AI editorial","pim_reviewed_date":"2026-10-04","pim_editorial_note":"Examples are calculations, not NHD lot results. Confirm project feasibility and document availability.","pim_review_status":"reviewed","pim_review_reason":"Source, arithmetic and search-intent checks; no independent human technical review recorded.","pim_creation_method":"AI-assisted writing, source checks and illustrated cover.","pim_sources":"[{\"title\":\"Thermo Fisher: Overview of mass spectrometry\",\"url\":\"https:\/\/www.thermofisher.com\/pl\/en\/home\/life-science\/protein-biology\/protein-biology-learning-center\/protein-biology-resource-library\/pierce-protein-methods\/overview-mass-spectrometry.html\",\"note\":\"Technical reference; numerical planning examples are original calculations.\"},{\"title\":\"Thermo Fisher: Charge assignment of isotopically resolved mass data\",\"url\":\"https:\/\/assets.thermofisher.com\/TFS-Assets\/CMD\/posters\/po-80036-asms22-charge-assignment-of-isotopically-po80036-en.pdf\",\"note\":\"Technical reference; numerical planning examples are original calculations.\"}]","footnotes":""},"categories":[20],"tags":[],"class_list":["post-3081","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-evidence-quality-guides"],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v28.0 (Yoast SEO v28.1) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>Why does a peptide mass spectrum show half the expected mass? - NHD<\/title>\n<meta name=\"description\" content=\"Peptide Raw Materials and Custom Peptide Synthesis\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/nhdbio.com\/fr\/exemple-simple-de-lcms-de-peptide-avec-etat-de-charge-m-z\/\" \/>\n<meta property=\"og:locale\" content=\"fr_FR\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Why does a peptide mass spectrum show half the expected mass?\" \/>\n<meta property=\"og:description\" content=\"Your peptide document lists a molecular mass near 2,000 Da, but the spectrum has a peak near 1,001. Has the supplier sent the wrong material? That number alone cannot answer the question. A mass spectrometer measures mass divided by charge, usually written as m\/z.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/nhdbio.com\/fr\/exemple-simple-de-lcms-de-peptide-avec-etat-de-charge-m-z\/\" \/>\n<meta property=\"og:site_name\" content=\"NHD\" \/>\n<meta property=\"article:published_time\" content=\"2026-10-03T20:25:51+00:00\" \/>\n<meta name=\"author\" content=\"NHD Technical Team\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:description\" content=\"Peptide Raw Materials and Custom Peptide Synthesis\" \/>\n<meta name=\"twitter:label1\" content=\"\u00c9crit par\" \/>\n\t<meta name=\"twitter:data1\" content=\"NHD Technical Team\" \/>\n\t<meta name=\"twitter:label2\" content=\"Dur\u00e9e de lecture estim\u00e9e\" \/>\n\t<meta name=\"twitter:data2\" content=\"2 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/nhdbio.com\\\/peptide-lcms-charge-state-mz-simple-example\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/nhdbio.com\\\/peptide-lcms-charge-state-mz-simple-example\\\/\"},\"author\":{\"name\":\"NHD Technical Team\",\"@id\":\"https:\\\/\\\/nhdbio.com\\\/#\\\/schema\\\/person\\\/0ffb0dec7fda0f720073fc468fac6fc1\"},\"headline\":\"Why does a peptide mass spectrum show half the expected mass?\",\"datePublished\":\"2026-10-03T20:25:51+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/nhdbio.com\\\/peptide-lcms-charge-state-mz-simple-example\\\/\"},\"wordCount\":378,\"commentCount\":0,\"publisher\":{\"@id\":\"https:\\\/\\\/nhdbio.com\\\/#organization\"},\"image\":{\"@id\":\"https:\\\/\\\/nhdbio.com\\\/peptide-lcms-charge-state-mz-simple-example\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/nhdbio.com\\\/wp-content\\\/uploads\\\/2026\\\/10\\\/charge-cover.png\",\"articleSection\":[\"Evidence &amp; Quality Guides\"],\"inLanguage\":\"fr-FR\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/nhdbio.com\\\/peptide-lcms-charge-state-mz-simple-example\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/nhdbio.com\\\/peptide-lcms-charge-state-mz-simple-example\\\/\",\"url\":\"https:\\\/\\\/nhdbio.com\\\/peptide-lcms-charge-state-mz-simple-example\\\/\",\"name\":\"Why does a peptide mass spectrum show half the expected mass? - NHD\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/nhdbio.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/nhdbio.com\\\/peptide-lcms-charge-state-mz-simple-example\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/nhdbio.com\\\/peptide-lcms-charge-state-mz-simple-example\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/nhdbio.com\\\/wp-content\\\/uploads\\\/2026\\\/10\\\/charge-cover.png\",\"datePublished\":\"2026-10-03T20:25:51+00:00\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/nhdbio.com\\\/peptide-lcms-charge-state-mz-simple-example\\\/#breadcrumb\"},\"inLanguage\":\"fr-FR\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/nhdbio.com\\\/peptide-lcms-charge-state-mz-simple-example\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"fr-FR\",\"@id\":\"https:\\\/\\\/nhdbio.com\\\/peptide-lcms-charge-state-mz-simple-example\\\/#primaryimage\",\"url\":\"https:\\\/\\\/nhdbio.com\\\/wp-content\\\/uploads\\\/2026\\\/10\\\/charge-cover.png\",\"contentUrl\":\"https:\\\/\\\/nhdbio.com\\\/wp-content\\\/uploads\\\/2026\\\/10\\\/charge-cover.png\",\"width\":1536,\"height\":1024,\"caption\":\"Illustration; not an experimental spectrum.\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/nhdbio.com\\\/peptide-lcms-charge-state-mz-simple-example\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/nhdbio.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Why does a peptide mass spectrum show half the expected mass?\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/nhdbio.com\\\/#website\",\"url\":\"https:\\\/\\\/nhdbio.com\\\/\",\"name\":\"NHD\",\"description\":\"Peptide Raw Materials and Custom Peptide Synthesis\",\"publisher\":{\"@id\":\"https:\\\/\\\/nhdbio.com\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/nhdbio.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"fr-FR\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/nhdbio.com\\\/#organization\",\"name\":\"NHD\",\"url\":\"https:\\\/\\\/nhdbio.com\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"fr-FR\",\"@id\":\"https:\\\/\\\/nhdbio.com\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/nhdbio.com\\\/wp-content\\\/uploads\\\/2026\\\/09\\\/codex-clipboard-354c928e-4b5b-482d-9261-02023d4c9680.png\",\"contentUrl\":\"https:\\\/\\\/nhdbio.com\\\/wp-content\\\/uploads\\\/2026\\\/09\\\/codex-clipboard-354c928e-4b5b-482d-9261-02023d4c9680.png\",\"width\":2172,\"height\":724,\"caption\":\"NHD\"},\"image\":{\"@id\":\"https:\\\/\\\/nhdbio.com\\\/#\\\/schema\\\/logo\\\/image\\\/\"}},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/nhdbio.com\\\/#\\\/schema\\\/person\\\/0ffb0dec7fda0f720073fc468fac6fc1\",\"name\":\"NHD Technical Team\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"fr-FR\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/8445618b3e2834fa0c7ae1a03a371ed002e9bf8d2cc1cd989dc4a71bb2b66110?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/8445618b3e2834fa0c7ae1a03a371ed002e9bf8d2cc1cd989dc4a71bb2b66110?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/8445618b3e2834fa0c7ae1a03a371ed002e9bf8d2cc1cd989dc4a71bb2b66110?s=96&d=mm&r=g\",\"caption\":\"NHD Technical Team\"},\"description\":\"NHD Technical Team maintains research-use catalog documentation and evidence summaries. Reviewed articles link to peer-reviewed papers, trial registries and regulatory records, retain null findings and study limitations, and distinguish published interventions from catalog materials. AI-assisted drafting may be used for structure; source links and evidence boundaries remain visible. This work is not independent peer review or medical advice.\",\"sameAs\":[\"https:\\\/\\\/nhdbio.com\"],\"url\":\"https:\\\/\\\/nhdbio.com\\\/fr\\\/author\\\/qianmiao-technical-team\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"Pourquoi un spectre de masse peptidique montre-t-il la moiti\u00e9 de la masse attendue ? - NHD","description":"Mati\u00e8res premi\u00e8res peptidiques et synth\u00e8se sur mesure","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/nhdbio.com\/fr\/exemple-simple-de-lcms-de-peptide-avec-etat-de-charge-m-z\/","og_locale":"fr_FR","og_type":"article","og_title":"Why does a peptide mass spectrum show half the expected mass?","og_description":"Your peptide document lists a molecular mass near 2,000 Da, but the spectrum has a peak near 1,001. Has the supplier sent the wrong material? That number alone cannot answer the question. A mass spectrometer measures mass divided by charge, usually written as m\/z.","og_url":"https:\/\/nhdbio.com\/fr\/exemple-simple-de-lcms-de-peptide-avec-etat-de-charge-m-z\/","og_site_name":"NHD","article_published_time":"2026-10-03T20:25:51+00:00","author":"NHD Technical Team","twitter_card":"summary_large_image","twitter_description":"Peptide Raw Materials and Custom Peptide Synthesis","twitter_misc":{"\u00c9crit par":"NHD Technical Team","Dur\u00e9e de lecture estim\u00e9e":"2 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/nhdbio.com\/peptide-lcms-charge-state-mz-simple-example\/#article","isPartOf":{"@id":"https:\/\/nhdbio.com\/peptide-lcms-charge-state-mz-simple-example\/"},"author":{"name":"NHD Technical Team","@id":"https:\/\/nhdbio.com\/#\/schema\/person\/0ffb0dec7fda0f720073fc468fac6fc1"},"headline":"Why does a peptide mass spectrum show half the expected mass?","datePublished":"2026-10-03T20:25:51+00:00","mainEntityOfPage":{"@id":"https:\/\/nhdbio.com\/peptide-lcms-charge-state-mz-simple-example\/"},"wordCount":378,"commentCount":0,"publisher":{"@id":"https:\/\/nhdbio.com\/#organization"},"image":{"@id":"https:\/\/nhdbio.com\/peptide-lcms-charge-state-mz-simple-example\/#primaryimage"},"thumbnailUrl":"https:\/\/nhdbio.com\/wp-content\/uploads\/2026\/10\/charge-cover.png","articleSection":["Evidence &amp; Quality Guides"],"inLanguage":"fr-FR","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/nhdbio.com\/peptide-lcms-charge-state-mz-simple-example\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/nhdbio.com\/peptide-lcms-charge-state-mz-simple-example\/","url":"https:\/\/nhdbio.com\/peptide-lcms-charge-state-mz-simple-example\/","name":"Pourquoi un spectre de masse peptidique montre-t-il la moiti\u00e9 de la masse attendue ? - NHD","isPartOf":{"@id":"https:\/\/nhdbio.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/nhdbio.com\/peptide-lcms-charge-state-mz-simple-example\/#primaryimage"},"image":{"@id":"https:\/\/nhdbio.com\/peptide-lcms-charge-state-mz-simple-example\/#primaryimage"},"thumbnailUrl":"https:\/\/nhdbio.com\/wp-content\/uploads\/2026\/10\/charge-cover.png","datePublished":"2026-10-03T20:25:51+00:00","breadcrumb":{"@id":"https:\/\/nhdbio.com\/peptide-lcms-charge-state-mz-simple-example\/#breadcrumb"},"inLanguage":"fr-FR","potentialAction":[{"@type":"ReadAction","target":["https:\/\/nhdbio.com\/peptide-lcms-charge-state-mz-simple-example\/"]}]},{"@type":"ImageObject","inLanguage":"fr-FR","@id":"https:\/\/nhdbio.com\/peptide-lcms-charge-state-mz-simple-example\/#primaryimage","url":"https:\/\/nhdbio.com\/wp-content\/uploads\/2026\/10\/charge-cover.png","contentUrl":"https:\/\/nhdbio.com\/wp-content\/uploads\/2026\/10\/charge-cover.png","width":1536,"height":1024,"caption":"Illustration; not an experimental spectrum."},{"@type":"BreadcrumbList","@id":"https:\/\/nhdbio.com\/peptide-lcms-charge-state-mz-simple-example\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/nhdbio.com\/"},{"@type":"ListItem","position":2,"name":"Why does a peptide mass spectrum show half the expected mass?"}]},{"@type":"WebSite","@id":"https:\/\/nhdbio.com\/#website","url":"https:\/\/nhdbio.com\/","name":"NHD","description":"Mati\u00e8res premi\u00e8res peptidiques et synth\u00e8se sur mesure","publisher":{"@id":"https:\/\/nhdbio.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/nhdbio.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"fr-FR"},{"@type":"Organization","@id":"https:\/\/nhdbio.com\/#organization","name":"NHD","url":"https:\/\/nhdbio.com\/","logo":{"@type":"ImageObject","inLanguage":"fr-FR","@id":"https:\/\/nhdbio.com\/#\/schema\/logo\/image\/","url":"https:\/\/nhdbio.com\/wp-content\/uploads\/2026\/09\/codex-clipboard-354c928e-4b5b-482d-9261-02023d4c9680.png","contentUrl":"https:\/\/nhdbio.com\/wp-content\/uploads\/2026\/09\/codex-clipboard-354c928e-4b5b-482d-9261-02023d4c9680.png","width":2172,"height":724,"caption":"NHD"},"image":{"@id":"https:\/\/nhdbio.com\/#\/schema\/logo\/image\/"}},{"@type":"Person","@id":"https:\/\/nhdbio.com\/#\/schema\/person\/0ffb0dec7fda0f720073fc468fac6fc1","name":"\u00c9quipe technique NHD","image":{"@type":"ImageObject","inLanguage":"fr-FR","@id":"https:\/\/secure.gravatar.com\/avatar\/8445618b3e2834fa0c7ae1a03a371ed002e9bf8d2cc1cd989dc4a71bb2b66110?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/8445618b3e2834fa0c7ae1a03a371ed002e9bf8d2cc1cd989dc4a71bb2b66110?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/8445618b3e2834fa0c7ae1a03a371ed002e9bf8d2cc1cd989dc4a71bb2b66110?s=96&d=mm&r=g","caption":"NHD Technical Team"},"description":"L'\u00e9quipe technique NHD maintient la documentation du catalogue d'utilisation de la recherche et les r\u00e9sum\u00e9s des preuves. Les articles examin\u00e9s renvoient \u00e0 des articles \u00e9valu\u00e9s par des pairs, \u00e0 des registres d'essais et \u00e0 des dossiers r\u00e9glementaires, conservent les r\u00e9sultats nuls et les limites des \u00e9tudes, et distinguent les interventions publi\u00e9es des documents du catalogue. Le dessin assist\u00e9 par AI peut \u00eatre utilis\u00e9 pour la structure\u00a0; les liens vers les sources et les limites des preuves restent visibles. Ce travail ne constitue pas un examen ind\u00e9pendant par des pairs ni un avis m\u00e9dical.","sameAs":["https:\/\/nhdbio.com"],"url":"https:\/\/nhdbio.com\/fr\/author\/qianmiao-technical-team\/"}]}},"_links":{"self":[{"href":"https:\/\/nhdbio.com\/fr\/wp-json\/wp\/v2\/posts\/3081","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/nhdbio.com\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/nhdbio.com\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/nhdbio.com\/fr\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/nhdbio.com\/fr\/wp-json\/wp\/v2\/comments?post=3081"}],"version-history":[{"count":1,"href":"https:\/\/nhdbio.com\/fr\/wp-json\/wp\/v2\/posts\/3081\/revisions"}],"predecessor-version":[{"id":3087,"href":"https:\/\/nhdbio.com\/fr\/wp-json\/wp\/v2\/posts\/3081\/revisions\/3087"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/nhdbio.com\/fr\/wp-json\/wp\/v2\/media\/3083"}],"wp:attachment":[{"href":"https:\/\/nhdbio.com\/fr\/wp-json\/wp\/v2\/media?parent=3081"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/nhdbio.com\/fr\/wp-json\/wp\/v2\/categories?post=3081"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/nhdbio.com\/fr\/wp-json\/wp\/v2\/tags?post=3081"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}