{"id":4121,"date":"2026-10-11T06:37:06","date_gmt":"2026-10-11T06:37:06","guid":{"rendered":"https:\/\/nhdbio.com\/?page_id=4121"},"modified":"2026-10-11T07:41:09","modified_gmt":"2026-10-11T07:41:09","slug":"%e3%83%9a%e3%83%97%e3%83%81%e3%83%89%e6%a4%9c%e9%87%8f%e7%b7%9a%e3%81%ae%e8%a8%88%e7%ae%97%e4%be%8b","status":"publish","type":"page","link":"https:\/\/nhdbio.com\/ja\/analytical-methods\/peptide-calibration-curve-worked-example\/","title":{"rendered":"\u30da\u30d7\u30c1\u30c9\u691c\u91cf\u7dda\uff1a\u672a\u77e5\u6fc3\u5ea6\u306e\u8a08\u7b97"},"content":{"rendered":"<p>\u6a5f\u5668\u306f6.2\u306e\u30b7\u30b0\u30ca\u30eb\u3092\u51fa\u3057\u307e\u3059\u304c\u3001\u5fc5\u8981\u306a\u306e\u306f\u6fc3\u5ea6\u3067\u3059\u3002\u3069\u3046\u3059\u308c\u3070\u4e00\u65b9\u304b\u3089\u4ed6\u65b9\u3078\u5909\u63db\u3067\u304d\u308b\u306e\u3067\u3057\u3087\u3046\u304b\u3002\u307e\u305a\u65e2\u77e5\u306e\u6fc3\u5ea6\u3092\u6e2c\u5b9a\u3057\u307e\u3059\u3002\u305d\u308c\u3089\u306e\u30b7\u30b0\u30ca\u30eb\u304b\u3089\u691c\u91cf\u7dda\u304c\u5f97\u3089\u308c\u3001\u9069\u5207\u306a\u6761\u4ef6\u4e0b\u3067\u672a\u77e5\u8a66\u6599\u306b\u4f7f\u3048\u307e\u3059\u3002<\/p>\n<h2>\u6fc3\u5ea6\u304c\u308f\u304b\u3063\u3066\u3044\u308b\u8a66\u6599\u304b\u3089\u59cb\u3081\u307e\u3059<\/h2>\n<p>Our teaching standards are 0, 1, 2, 4 and 8 \u00b5M. Measure them using the chosen method, then plot concentration on the horizontal axis and signal on the vertical axis.<\/p>\n<p>\u6fc3\u5ea6\u306f\u4fe1\u983c\u3067\u304d\u308b\u3082\u306e\u3067\u306a\u3051\u308c\u3070\u306a\u308a\u307e\u305b\u3093\u3002\u8aa4\u3063\u3066\u8abf\u88fd\u3057\u305f\u6a19\u6e96\u54c1\u304b\u3089\u4f5c\u3063\u305f\u691c\u91cf\u7dda\u306f\u3001\u304d\u308c\u3044\u306b\u898b\u3048\u3066\u3082\u8aa4\u3063\u305f\u7d50\u679c\u3092\u4e0e\u3048\u308b\u3053\u3068\u304c\u3042\u308a\u307e\u3059\u3002\u6a19\u6e96\u54c1\u3068\u672a\u77e5\u8a66\u6599\u306b\u306f\u3001\u9069\u5207\u306b\u6bd4\u8f03\u3067\u304d\u308b\u8abf\u88fd\u6761\u4ef6\u3068\u6e2c\u5b9a\u6761\u4ef6\u3082\u5fc5\u8981\u3067\u3059\u3002<\/p>\n<figure><img decoding=\"async\" src=\"https:\/\/nhdbio.com\/wp-content\/plugins\/nhd-content-refresh\/teaching-images\/t16\/en\/1.png\" alt=\"Figure 1. Teaching standards at 0, 1, 2, 4 and 8 \u00b5M span the unknown.\"><figcaption>\u56f31\u3002\u65e2\u77e5\u306e\u6fc3\u5ea6\u304c\u6e2c\u5b9a\u30b7\u30b0\u30ca\u30eb\u3068\u306e\u95a2\u4fc2\u3092\u78ba\u7acb\u3057\u307e\u3059\u3002<\/figcaption><\/figure>\n<h2>y = 2x + 0.2 \u306f\u4f55\u3092\u610f\u5473\u3059\u308b\u306e\u3067\u3057\u3087\u3046\u304b\u3002<\/h2>\n<p>Suppose the fitted relationship is y = 2x + 0.2. Here x is concentration in \u00b5M, and y is the instrument response in example units. Each extra \u00b5M adds two response units; the intercept is 0.2.<\/p>\n<p>To find x from a signal, reverse the calculation: subtract 0.2, then divide by two. Follow the method\u2019s blank correction; do not subtract the same background twice.<\/p>\n<h2>\u672a\u77e5\u306e\u30b7\u30b0\u30ca\u30eb\u3092\u4f7f\u7528\u3059\u308b<\/h2>\n<p>For y = 6.2, x = (6.2 \u2212 0.2) \u00f7 2 = 3 \u00b5M. This lies within the illustrated 0\u20138 \u00b5M span.<\/p>\n<p>If the unknown is outside the method\u2019s established working range, do not assume the line remains valid indefinitely. The laboratory may need a suitable dilution or another validated measurement arrangement.<\/p>\n<figure><img decoding=\"async\" src=\"https:\/\/nhdbio.com\/wp-content\/plugins\/nhd-content-refresh\/teaching-images\/t16\/en\/2.png\" alt=\"Figure 2. In the invented model y=2x+0.2, signal 6.2 corresponds to concentration 3 \u00b5M.\"><figcaption>Figure 2. In this teaching model, a response of 6.2 corresponds to 3 \u00b5M.<\/figcaption><\/figure>\n<h2>\u5143\u306e\u8a66\u6599\u306f\u5e0c\u91c8\u3055\u308c\u307e\u3057\u305f\u304b\uff1f<\/h2>\n<p>If the sample was diluted fivefold before measurement, the measured solution is 3 \u00b5M, while the original is 3 \u00d7 5 = 15 \u00b5M, assuming no loss.<\/p>\n<p>\u8a66\u6599 1 \u90e8\u306b\u5e0c\u91c8\u6db2 4 \u90e8\u3092\u52a0\u3048\u308b\u3068\u5168\u4f53\u3067 5 \u90e8\u306b\u306a\u308a\u307e\u3059\u3002\u3053\u308c\u306f 4 \u500d\u3067\u306f\u306a\u304f 5 \u500d\u5e0c\u91c8\u3067\u3059\u3002\u6700\u7d42\u4f53\u7a4d\u3068\u79fb\u3057\u305f\u8a66\u6599\u4f53\u7a4d\u3092\u8a18\u9332\u3057\u3066\u304f\u3060\u3055\u3044\u3002<\/p>\n<figure><img decoding=\"async\" src=\"https:\/\/nhdbio.com\/wp-content\/plugins\/nhd-content-refresh\/teaching-images\/t16\/en\/3.png\" alt=\"Figure 3. A dilution factor of five converts 3 \u00b5M in the measured solution to 15 \u00b5M in the original.\"><figcaption>\u56f3 3\u3002\u5e0c\u91c8\u4fc2\u6570\u3092\u9069\u7528\u3057\u3066\u5143\u306e\u6fc3\u5ea6\u3092\u6c42\u3081\u307e\u3059\u3002<\/figcaption><\/figure>\n<h2>\u307e\u3063\u3059\u3050\u306b\u898b\u3048\u308b\u7dda\u3067\u3082\u78ba\u8a8d\u304c\u5fc5\u8981\u3067\u3059<\/h2>\n<p>Not necessarily. A high R\u00b2 describes fit to the data; it does not alone prove accurate low-concentration results. Repeatability, background, recovery and interference also need appropriate checks.<\/p>\n<div class=\"exercise\"><strong>\u5fdc\u7b54\u306f 10.2 \u3067\u3001\u8a66\u6599\u306f 3 \u500d\u306b\u5e0c\u91c8\u3055\u308c\u3066\u3044\u307e\u3057\u305f\u3002\u5143\u306e\u6fc3\u5ea6\u306f\u3044\u304f\u3089\u3067\u3057\u305f\u304b\uff1f<\/strong><\/p>\n<details>\n<summary>\u7b54\u3048\u3092\u898b\u308b<\/summary>\n<p>The measured solution is (10.2 \u2212 0.2) \u00f7 2 = 5 \u00b5M. The original is 5 \u00d7 3 = 15 \u00b5M.<\/p>\n<\/details>\n<\/div>\n<h2>KPV\u307e\u305f\u306fLL-37\u6e2c\u5b9a\u306e\u8a08\u753b<\/h2>\n<p>KPV\u307e\u305f\u306fLL-37\u306e\u5b9a\u91cf\u3067\u306f\u3001\u76ee\u7684\u30da\u30d7\u30c1\u30c9\u306e\u91cf\u306e\u7d50\u679c\u304c\u5fc5\u8981\u306a\u306e\u304b\u3001\u30e1\u30bd\u30c3\u30c9\u7528\u306e\u9069\u5207\u306a\u6a19\u6e96\u7269\u8cea\u304c\u5fc5\u8981\u306a\u306e\u304b\u3092\u8aac\u660e\u3057\u3066\u304f\u3060\u3055\u3044\u3002\u30ab\u30bf\u30ed\u30b0\u88fd\u54c1\u306f\u81ea\u52d5\u7684\u306b\u8a8d\u8a3c\u6a19\u6e96\u7269\u8cea\u306b\u306a\u308b\u308f\u3051\u3067\u306f\u3042\u308a\u307e\u305b\u3093\u3002<\/p>\n<p><a href=\"https:\/\/nhdbio.com\/ja\/%e8%a3%bd%e5%93%81\/kpv\/\">KPV<\/a> \/ <a href=\"https:\/\/nhdbio.com\/ja\/%e8%a3%bd%e5%93%81\/ll-37\/\">LL-37<\/a><\/p>\n<p><a href=\"https:\/\/nhdbio.com\/ja\/%e5%bc%95%e7%94%a8\/\">\u8cc7\u6750\u304a\u3088\u3073\u6587\u66f8\u306e\u8981\u4ef6\u306b\u3064\u3044\u3066NHD\u3068\u76f8\u8ac7\u3059\u308b<\/a> \u00b7 <a href=\"https:\/\/nhdbio.com\/ja\/%e5%88%86%e6%9e%90%e6%89%8b%e6%b3%95\/%e5%88%86%e6%9e%90%e6%b3%95%e3%81%ae%e3%83%90%e3%83%aa%e3%83%87%e3%83%bc%e3%82%b7%e3%83%a7%e3%83%b3\/\">\u5206\u6790\u30ac\u30a4\u30c9\u3092\u7d9a\u3051\u308b<\/a><\/p>\n<footer><strong>\u51fa\u5178\u3068\u4f8b\u306e\u6ce8\u8a18<\/strong><\/p>\n<p>\u6570\u5024\u3068\u66f2\u7dda\u306f\u6559\u80b2\u7528\u306e\u4f8b\u3067\u3042\u308a\u3001\u88fd\u54c1\u30d0\u30c3\u30c1\u306e\u8a66\u9a13\u7d50\u679c\u3067\u306f\u3042\u308a\u307e\u305b\u3093\u3002\u51fa\u5178\u78ba\u8a8d\u65e5\uff1a11 \u5e74 2026 \u6708\u3002<\/p>\n<ul>\n<li><a href=\"https:\/\/database.ich.org\/sites\/default\/files\/ICH_Q2(R2)_Guideline_2023_1130_ErrorCorrection_2025.pdf\">ICH Q2(R2) \u00b7 analytical validation<\/a><\/li>\n<li><a href=\"https:\/\/www.bachem.com\/knowledge-center\/quality-control-of-amino-acids-peptides-a-guide\/\">Bachem \u00b7 peptide quality control<\/a><\/li>\n<\/ul>\n<p>AI\u652f\u63f4\u306b\u3088\u308b\u57f7\u7b46\u304a\u3088\u3073\u60c5\u5831\u6e90\u306e\u30ec\u30d3\u30e5\u30fc\u3002\u30ab\u30bf\u30ed\u30b0\u8cc7\u6599\u306f\u7814\u7a76\u3001\u958b\u767a\u3001\u88fd\u9020\u7528\u3067\u3042\u308a\u3001\u4eba\u307e\u305f\u306f\u52d5\u7269\u3078\u306e\u4f7f\u7528\u3092\u76ee\u7684\u3068\u3057\u3066\u3044\u307e\u305b\u3093\u3002<\/p>\n<\/footer>","protected":false},"excerpt":{"rendered":"<p>\u65e2\u77e5\u306e\u6fc3\u5ea6\u3068\u6a5f\u5668\u30b7\u30b0\u30ca\u30eb\u306e\u9593\u306e\u95a2\u9023\u6027\u3092\u69cb\u7bc9\u3057\u307e\u3059\u3002<\/p>","protected":false},"author":1,"featured_media":0,"parent":865,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"footnotes":""},"class_list":["post-4121","page","type-page","status-publish","hentry"],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v28.0 (Yoast SEO v28.1) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>A Peptide Calibration Curve: Calculate an Unknown Concentration | NHD<\/title>\n<meta name=\"description\" content=\"Build the connection between a known concentration and an instrument signal.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/nhdbio.com\/ja\/\u5206\u6790\u624b\u6cd5\/\u30da\u30d7\u30c1\u30c9\u691c\u91cf\u7dda\u306e\u8a08\u7b97\u4f8b\/\" \/>\n<meta property=\"og:locale\" content=\"ja_JP\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"A Peptide Calibration Curve: Calculate an Unknown Concentration\" \/>\n<meta property=\"og:description\" content=\"Build the connection between a known concentration and an instrument signal.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/nhdbio.com\/ja\/\u5206\u6790\u624b\u6cd5\/\u30da\u30d7\u30c1\u30c9\u691c\u91cf\u7dda\u306e\u8a08\u7b97\u4f8b\/\" \/>\n<meta property=\"og:site_name\" content=\"NHD\" \/>\n<meta property=\"article:modified_time\" content=\"2026-10-11T07:41:09+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/nhdbio.com\/wp-content\/plugins\/nhd-content-refresh\/teaching-images\/t16\/en\/1.png\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:description\" content=\"Peptide Raw Materials and Custom Peptide Synthesis\" \/>\n<meta name=\"twitter:label1\" content=\"\u63a8\u5b9a\u8aad\u307f\u53d6\u308a\u6642\u9593\" \/>\n\t<meta name=\"twitter:data1\" content=\"2\u5206\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/nhdbio.com\\\/analytical-methods\\\/peptide-calibration-curve-worked-example\\\/\",\"url\":\"https:\\\/\\\/nhdbio.com\\\/analytical-methods\\\/peptide-calibration-curve-worked-example\\\/\",\"name\":\"A Peptide Calibration Curve: Calculate an Unknown Concentration | NHD\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/nhdbio.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/nhdbio.com\\\/analytical-methods\\\/peptide-calibration-curve-worked-example\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/nhdbio.com\\\/analytical-methods\\\/peptide-calibration-curve-worked-example\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/nhdbio.com\\\/wp-content\\\/plugins\\\/nhd-content-refresh\\\/teaching-images\\\/t16\\\/en\\\/1.png\",\"datePublished\":\"2026-10-11T06:37:06+00:00\",\"dateModified\":\"2026-10-11T07:41:09+00:00\",\"description\":\"Build the connection between a known concentration and an instrument signal.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/nhdbio.com\\\/analytical-methods\\\/peptide-calibration-curve-worked-example\\\/#breadcrumb\"},\"inLanguage\":\"ja\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/nhdbio.com\\\/analytical-methods\\\/peptide-calibration-curve-worked-example\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"ja\",\"@id\":\"https:\\\/\\\/nhdbio.com\\\/analytical-methods\\\/peptide-calibration-curve-worked-example\\\/#primaryimage\",\"url\":\"https:\\\/\\\/nhdbio.com\\\/wp-content\\\/plugins\\\/nhd-content-refresh\\\/teaching-images\\\/t16\\\/en\\\/1.png\",\"contentUrl\":\"https:\\\/\\\/nhdbio.com\\\/wp-content\\\/plugins\\\/nhd-content-refresh\\\/teaching-images\\\/t16\\\/en\\\/1.png\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/nhdbio.com\\\/analytical-methods\\\/peptide-calibration-curve-worked-example\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/nhdbio.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Analytical Methods &#038; COA Knowledge Center\",\"item\":\"https:\\\/\\\/nhdbio.com\\\/analytical-methods\\\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"A Peptide Calibration Curve: Calculate an Unknown Concentration\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/nhdbio.com\\\/#website\",\"url\":\"https:\\\/\\\/nhdbio.com\\\/\",\"name\":\"NHD\",\"description\":\"Peptide Raw Materials and Custom Peptide Synthesis\",\"publisher\":{\"@id\":\"https:\\\/\\\/nhdbio.com\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/nhdbio.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"ja\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/nhdbio.com\\\/#organization\",\"name\":\"NHD\",\"url\":\"https:\\\/\\\/nhdbio.com\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"ja\",\"@id\":\"https:\\\/\\\/nhdbio.com\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/nhdbio.com\\\/wp-content\\\/uploads\\\/2026\\\/09\\\/codex-clipboard-354c928e-4b5b-482d-9261-02023d4c9680.png\",\"contentUrl\":\"https:\\\/\\\/nhdbio.com\\\/wp-content\\\/uploads\\\/2026\\\/09\\\/codex-clipboard-354c928e-4b5b-482d-9261-02023d4c9680.png\",\"width\":2172,\"height\":724,\"caption\":\"NHD\"},\"image\":{\"@id\":\"https:\\\/\\\/nhdbio.com\\\/#\\\/schema\\\/logo\\\/image\\\/\"}}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"\u30da\u30d7\u30c1\u30c9\u691c\u91cf\u7dda\uff1a\u672a\u77e5\u6fc3\u5ea6\u306e\u8a08\u7b97 | NHD","description":"\u65e2\u77e5\u306e\u6fc3\u5ea6\u3068\u6a5f\u5668\u30b7\u30b0\u30ca\u30eb\u306e\u9593\u306e\u95a2\u9023\u6027\u3092\u69cb\u7bc9\u3057\u307e\u3059\u3002","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/nhdbio.com\/ja\/\u5206\u6790\u624b\u6cd5\/\u30da\u30d7\u30c1\u30c9\u691c\u91cf\u7dda\u306e\u8a08\u7b97\u4f8b\/","og_locale":"ja_JP","og_type":"article","og_title":"A Peptide Calibration Curve: Calculate an Unknown Concentration","og_description":"Build the connection between a known concentration and an instrument signal.","og_url":"https:\/\/nhdbio.com\/ja\/\u5206\u6790\u624b\u6cd5\/\u30da\u30d7\u30c1\u30c9\u691c\u91cf\u7dda\u306e\u8a08\u7b97\u4f8b\/","og_site_name":"NHD","article_modified_time":"2026-10-11T07:41:09+00:00","og_image":[{"url":"https:\/\/nhdbio.com\/wp-content\/plugins\/nhd-content-refresh\/teaching-images\/t16\/en\/1.png","type":"","width":"","height":""}],"twitter_card":"summary_large_image","twitter_description":"Peptide Raw Materials and Custom Peptide Synthesis","twitter_misc":{"\u63a8\u5b9a\u8aad\u307f\u53d6\u308a\u6642\u9593":"2\u5206"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/nhdbio.com\/analytical-methods\/peptide-calibration-curve-worked-example\/","url":"https:\/\/nhdbio.com\/analytical-methods\/peptide-calibration-curve-worked-example\/","name":"\u30da\u30d7\u30c1\u30c9\u691c\u91cf\u7dda\uff1a\u672a\u77e5\u6fc3\u5ea6\u306e\u8a08\u7b97 | NHD","isPartOf":{"@id":"https:\/\/nhdbio.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/nhdbio.com\/analytical-methods\/peptide-calibration-curve-worked-example\/#primaryimage"},"image":{"@id":"https:\/\/nhdbio.com\/analytical-methods\/peptide-calibration-curve-worked-example\/#primaryimage"},"thumbnailUrl":"https:\/\/nhdbio.com\/wp-content\/plugins\/nhd-content-refresh\/teaching-images\/t16\/en\/1.png","datePublished":"2026-10-11T06:37:06+00:00","dateModified":"2026-10-11T07:41:09+00:00","description":"\u65e2\u77e5\u306e\u6fc3\u5ea6\u3068\u6a5f\u5668\u30b7\u30b0\u30ca\u30eb\u306e\u9593\u306e\u95a2\u9023\u6027\u3092\u69cb\u7bc9\u3057\u307e\u3059\u3002","breadcrumb":{"@id":"https:\/\/nhdbio.com\/analytical-methods\/peptide-calibration-curve-worked-example\/#breadcrumb"},"inLanguage":"ja","potentialAction":[{"@type":"ReadAction","target":["https:\/\/nhdbio.com\/analytical-methods\/peptide-calibration-curve-worked-example\/"]}]},{"@type":"ImageObject","inLanguage":"ja","@id":"https:\/\/nhdbio.com\/analytical-methods\/peptide-calibration-curve-worked-example\/#primaryimage","url":"https:\/\/nhdbio.com\/wp-content\/plugins\/nhd-content-refresh\/teaching-images\/t16\/en\/1.png","contentUrl":"https:\/\/nhdbio.com\/wp-content\/plugins\/nhd-content-refresh\/teaching-images\/t16\/en\/1.png"},{"@type":"BreadcrumbList","@id":"https:\/\/nhdbio.com\/analytical-methods\/peptide-calibration-curve-worked-example\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/nhdbio.com\/"},{"@type":"ListItem","position":2,"name":"Analytical Methods &#038; COA Knowledge Center","item":"https:\/\/nhdbio.com\/analytical-methods\/"},{"@type":"ListItem","position":3,"name":"A Peptide Calibration Curve: Calculate an Unknown Concentration"}]},{"@type":"WebSite","@id":"https:\/\/nhdbio.com\/#website","url":"https:\/\/nhdbio.com\/","name":"NHD","description":"\u30da\u30d7\u30c1\u30c9\u539f\u6599\u30fb\u30ab\u30b9\u30bf\u30e0\u30da\u30d7\u30c1\u30c9\u5408\u6210","publisher":{"@id":"https:\/\/nhdbio.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/nhdbio.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"ja"},{"@type":"Organization","@id":"https:\/\/nhdbio.com\/#organization","name":"NHD","url":"https:\/\/nhdbio.com\/","logo":{"@type":"ImageObject","inLanguage":"ja","@id":"https:\/\/nhdbio.com\/#\/schema\/logo\/image\/","url":"https:\/\/nhdbio.com\/wp-content\/uploads\/2026\/09\/codex-clipboard-354c928e-4b5b-482d-9261-02023d4c9680.png","contentUrl":"https:\/\/nhdbio.com\/wp-content\/uploads\/2026\/09\/codex-clipboard-354c928e-4b5b-482d-9261-02023d4c9680.png","width":2172,"height":724,"caption":"NHD"},"image":{"@id":"https:\/\/nhdbio.com\/#\/schema\/logo\/image\/"}}]}},"_links":{"self":[{"href":"https:\/\/nhdbio.com\/ja\/wp-json\/wp\/v2\/pages\/4121","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/nhdbio.com\/ja\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/nhdbio.com\/ja\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/nhdbio.com\/ja\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/nhdbio.com\/ja\/wp-json\/wp\/v2\/comments?post=4121"}],"version-history":[{"count":4,"href":"https:\/\/nhdbio.com\/ja\/wp-json\/wp\/v2\/pages\/4121\/revisions"}],"predecessor-version":[{"id":4171,"href":"https:\/\/nhdbio.com\/ja\/wp-json\/wp\/v2\/pages\/4121\/revisions\/4171"}],"up":[{"embeddable":true,"href":"https:\/\/nhdbio.com\/ja\/wp-json\/wp\/v2\/pages\/865"}],"wp:attachment":[{"href":"https:\/\/nhdbio.com\/ja\/wp-json\/wp\/v2\/media?parent=4121"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}