{"id":866,"date":"2026-09-02T06:35:32","date_gmt":"2026-09-02T06:35:32","guid":{"rendered":"https:\/\/nhdbio.com\/analytical-methods\/hplc-peptide-purity\/"},"modified":"2026-10-11T05:22:36","modified_gmt":"2026-10-11T05:22:36","slug":"hplc%e3%81%ab%e3%82%88%e3%82%8b%e3%83%9a%e3%83%97%e3%83%81%e3%83%89%e3%81%ae%e7%b4%94%e5%ba%a6","status":"publish","type":"page","link":"https:\/\/nhdbio.com\/ja\/analytical-methods\/hplc-peptide-purity\/","title":{"rendered":"HPLC \u30da\u30d7\u30c1\u30c9\u7d14\u5ea6\uff1a98% \u306e\u7d50\u679c\u3092\u8aad\u307f\u89e3\u304f"},"content":{"rendered":"<p>Two peptide reports both say 98%. One includes a complete graph and area table; the other shows only a cropped main peak. The headline number is the same, but the information you can check is different.<\/p>\n<p>We will calculate a result, change one calculation choice and then separate chromatographic purity from the amount of peptide in a vial. You do not need to operate an HPLC instrument to follow the lesson.<\/p>\n<h2>1\u3002HPLC\u306f\u4f55\u3092\u5206\u96e2\u3057\u307e\u3059\u304b\uff1f<\/h2>\n<p>HPLC passes a sample through a column and records a detector signal over time. Components that behave differently in the method can appear as separate peaks. Imagine several runners reaching a finish line at different times: the instrument records their arrival rather than photographing the whole starting group.<\/p>\n<figure><img decoding=\"async\" src=\"https:\/\/nhdbio.com\/wp-content\/plugins\/nhd-content-refresh\/guide-images\/866\/en\/1.png\" alt=\"Figure 1. A simulated separation: sample, column and detected peaks. This is a teaching model, not an instrument setup diagram.\"><figcaption>Figure 1. A simulated separation: sample, column and detected peaks. This is a teaching model, not an instrument setup diagram.<\/figcaption><\/figure>\n<p>The horizontal axis is time. The vertical axis is detector response. In a UV method, the selected wavelength matters. A component that responds weakly or does not appear as a separate peak may not be represented fairly by its apparent area.<\/p>\n<h2>2\u3002\u9762\u7a4d\u8868\u304b\u308998%\u3092\u8a08\u7b97\u3057\u3066\u304f\u3060\u3055\u3044<\/h2>\n<p>Assume the target peak has already been assigned, every listed peak is included and no response-factor correction is applied. Read the area table rather than estimating from the picture.<\/p>\n<table>\n<thead>\n<tr>\n<th>\u30d4\u30fc\u30af<\/th>\n<th>Area<\/th>\n<th>Share<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>\u30bf\u30fc\u30b2\u30c3\u30c8<\/td>\n<td>980<\/td>\n<td>98%<\/td>\n<\/tr>\n<tr>\n<td>Other peak A<\/td>\n<td>12<\/td>\n<td>1.2%<\/td>\n<\/tr>\n<tr>\n<td>Other peak B<\/td>\n<td>8<\/td>\n<td>0.8%<\/td>\n<\/tr>\n<tr>\n<td>\u5408\u8a08<\/td>\n<td>1,000<\/td>\n<td>100%<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>Add the included areas: 980 + 12 + 8 = 1,000. Divide the target area by that total.<\/p>\n<p class=\"formula\">980 \u00f7 1,000 \u00d7 100% = 98%<\/p>\n<p>This result means 98% of the included detector area belongs to the assigned target peak. It is not a direct weighing of the powder.<\/p>\n<figure><img decoding=\"async\" src=\"https:\/\/nhdbio.com\/wp-content\/plugins\/nhd-content-refresh\/guide-images\/866\/en\/2.png\" alt=\"Figure 2. The same included area shown as a 98-to-2 split. The proportions come only from this invented area table.\"><figcaption>Figure 2. The same included area shown as a 98-to-2 split. The proportions come only from this invented area table.<\/figcaption><\/figure>\n<h2>3\u3002\u30d4\u30fc\u30af\u3092\u9664\u5916\u3059\u308b\u3068\u3001\u306a\u305c\u6570\u5024\u304c\u5909\u308f\u308b\u306e\u3067\u3059\u304b\uff1f<\/h2>\n<p>Suppose the peak with area 12 is left out. The new total is 988, so 980 \u00f7 988 \u00d7 100% is about 99.19%. The sample has not changed. The denominator has.<\/p>\n<p>An exclusion can be justified when the analytical procedure identifies a solvent or system signal that should not be counted. It should have an explanation. Agilent describes how integration settings affect peak handling; this is why the processing method deserves attention alongside the graph.<\/p>\n<figure><img decoding=\"async\" src=\"https:\/\/nhdbio.com\/wp-content\/plugins\/nhd-content-refresh\/guide-images\/866\/en\/3.png\" alt=\"Figure 3. Changing the denominator changes the percentage: 98.00% versus 99.19%. Teaching arithmetic; neither is an NHD result.\"><figcaption>Figure 3. Changing the denominator changes the percentage: 98.00% versus 99.19%. Teaching arithmetic; neither is an NHD result.<\/figcaption><\/figure>\n<h2>4. A larger number is not the whole comparison<\/h2>\n<p>Before comparing 98% with 99%, ask whether both tests used an equivalent method and reporting basis. Check detection wavelength, separation, target assignment and integration rules. A shoulder may hide an unresolved component; a smooth-looking peak alone cannot rule that out.<\/p>\n<p>HPLC also does not answer every other quality question. Identity, water, residual solvents and endotoxin need evidence appropriate to those questions. Do not substitute the purity figure for a test that was not performed.<\/p>\n<h2>5. Do not turn area purity into milligrams<\/h2>\n<p>A vial labeled 10 mg with 98% HPLC area purity does not establish 9.8 mg of target peptide. The weighed powder may contain non-peptide material, and area response is a different measurement. If your assay needs a known target concentration, request a suitable content or assay result and its basis.<\/p>\n<div class=\"exercise\"><strong>Try it: target area 475; other included areas total 25. What is the area purity?<\/strong><\/p>\n<details>\n<summary>\u7b54\u3048\u3092\u78ba\u8a8d\u3059\u308b<\/summary>\n<p>475 \u00f7 (475 + 25) \u00d7 100% = 95%. This is an area percentage, not a mass percentage.<\/p>\n<\/details>\n<\/div>\n<h2>6. Read an HPLC report in this order<\/h2>\n<p>First match the sample and lot. Then find the method, full graph, target assignment and area table. Recalculate the percentage. Finally ask about shoulders, omitted signals and unavailable tests. If an item is missing, describe the missing item rather than deciding from a cropped image that the material is good or bad.<\/p>\n<h2>\u3053\u306e\u30ac\u30a4\u30c9\u3092\u88fd\u54c1\u306b\u95a2\u3059\u308b\u304a\u554f\u3044\u5408\u308f\u305b\u3067\u3054\u5229\u7528\u304f\u3060\u3055\u3044<\/h2>\n<p>\u4ee5\u4e0b\u306e\u3088\u3046\u306a\u6750\u6599\u306b\u3064\u3044\u3066\u306f <a href=\"https:\/\/nhdbio.com\/ja\/%e8%a3%bd%e5%93%81\/ghk-cu\/\">GHK-Cu<\/a>\u3001<a href=\"https:\/\/nhdbio.com\/ja\/%e8%a3%bd%e5%93%81\/ll-37\/\">LL-37<\/a>\u3001\u307e\u305a\u6b63\u78ba\u306a\u5f62\u614b\u3001\u6570\u91cf\u3001\u7814\u7a76\u4e0a\u306e\u7591\u554f\u70b9\u3092\u7279\u5b9a\u3057\u3066\u304f\u3060\u3055\u3044\u3002\u6b21\u306b\u3001\u8a72\u5f53\u30ed\u30c3\u30c8\u306b\u3064\u3044\u3066\u5229\u7528\u53ef\u80fd\u306a\u8a18\u9332\u3092\u5c0b\u306d\u3066\u304f\u3060\u3055\u3044\u3002\u88fd\u54c1\u540d\u304c\u4e00\u81f4\u3057\u3066\u3044\u3066\u3082\u3001\u7570\u306a\u308b\u4ed5\u69d8\u304c\u4e92\u63db\u6027\u3092\u6301\u3064\u308f\u3051\u3067\u306f\u3042\u308a\u307e\u305b\u3093\u3002<\/p>\n<div class=\"note\"><strong>\u9001\u4fe1\u3067\u304d\u308b\u4f9d\u983c\u6587\uff1a<\/strong> \u8a08\u753b\u4e2d\u306e\u7814\u7a76\u306b\u5fc5\u8981\u306a\u6750\u6599\u4ed5\u69d8\u304a\u3088\u3073\u5229\u7528\u53ef\u80fd\u306a\u30ed\u30c3\u30c8\u6587\u66f8\u3092\u78ba\u8a8d\u3057\u3066\u304f\u3060\u3055\u3044\u3002\u672a\u8a66\u9a13\u306e\u9805\u76ee\u3092\u7279\u5b9a\u3057\u3066\u304f\u3060\u3055\u3044\u3002\u5272\u5408\u3084\u542b\u6709\u91cf\u306e\u7d50\u679c\u306b\u3064\u3044\u3066\u306f\u3001\u65b9\u6cd5\u3001\u5358\u4f4d\u3001\u5831\u544a\u57fa\u6e96\u3092\u542b\u3081\u3066\u304f\u3060\u3055\u3044\u3002<\/div>\n<p><a href=\"https:\/\/nhdbio.com\/ja\/%e5%bc%95%e7%94%a8\/\">\u88fd\u54c1\u304a\u3088\u3073\u6587\u66f8\u8981\u4ef6\u306b\u3064\u3044\u3066NHD\u306b\u3054\u76f8\u8ac7\u304f\u3060\u3055\u3044<\/a>\u3002\u5b66\u7fd2\u3092\u7d9a\u3051\u308b\uff1a <a href=\"https:\/\/nhdbio.com\/ja\/%e5%88%86%e6%9e%90%e6%89%8b%e6%b3%95\/%e3%82%af%e3%83%ad%e3%83%9e%e3%83%88%e3%82%b0%e3%83%a9%e3%83%a0%e3%81%ae%e8%a7%a3%e9%87%88\/\">\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30e0\u306e\u8aad\u307f\u65b9<\/a> \/ <a href=\"https:\/\/nhdbio.com\/ja\/%e5%88%86%e6%9e%90%e6%89%8b%e6%b3%95\/%e3%83%9a%e3%83%97%e3%83%81%e3%83%89%e5%90%ab%e6%9c%89%e9%87%8f%e3%81%a8%e7%b4%94%e5%ba%a6%e3%81%ae%e9%96%a2%e4%bf%82\/\">\u7d14\u5ea6\u3068\u542b\u91cf<\/a>.<\/p>\n<footer><strong>\u51fa\u5178\u3068\u6559\u80b2\u7528\u56f3\u8868<\/strong><\/p>\n<p>\u78ba\u8a8d\u6e08\u307f\u306e\u6280\u8853\u60c5\u5831\u6e90: 11 October 2026\u3002\u3053\u306e\u30da\u30fc\u30b8\u306e\u6570\u5024\u3001\u30b5\u30f3\u30d7\u30eb\u8b58\u5225\u5b50\u3001\u66f2\u7dda\u3001\u6587\u66f8\u4f8b\u306f\u3001\u6559\u80b2\u7528\u306b\u4f5c\u3089\u308c\u305f\u67b6\u7a7a\u306e\u4f8b\u3067\u3042\u308a\u3001NHD \u306e\u7d50\u679c\u3001\u88fd\u54c1\u4ed5\u69d8\u3001\u5b9f\u969b\u306e\u8a3c\u660e\u66f8\u3067\u306f\u3042\u308a\u307e\u305b\u3093\u3002\u3042\u306a\u305f\u306e\u5b9f\u9a13\u3078\u306e\u9069\u7528\u53ef\u5426\u3092\u78ba\u8a8d\u3057\u3066\u304f\u3060\u3055\u3044\u3002<\/p>\n<ul>\n<li><a href=\"https:\/\/www.agilent.com\/about\/data-integrity\/en\/5-tips-chromatographic-integration.html\">Agilent: chromatographic integration<\/a><\/li>\n<li><a href=\"https:\/\/www.bachem.com\/knowledge-center\/quality-control-of-amino-acids-peptides-a-guide\/\">Bachem\uff1a\u30da\u30d7\u30c1\u30c9\u306e\u54c1\u8cea\u7ba1\u7406<\/a><\/li>\n<\/ul>\n<p>AI\u652f\u63f4\u306b\u3088\u308b\u57f7\u7b46\u3068\u60c5\u5831\u6e90\u306e\u78ba\u8a8d\u3002\u3053\u306e\u5165\u9580\u30ac\u30a4\u30c9\u306f\u5b9f\u9a13\u5ba4\u3067\u306e\u89e3\u91c8\u306b\u4ee3\u308f\u308b\u3082\u306e\u3067\u306f\u3042\u308a\u307e\u305b\u3093\u3002\u30ab\u30bf\u30ed\u30b0\u63b2\u8f09\u306e\u6750\u6599\u306f\u7814\u7a76\u3001\u958b\u767a\u3001\u88fd\u9020\u7528\u3067\u3042\u308a\u3001\u4eba\u307e\u305f\u306f\u52d5\u7269\u3078\u306e\u4f7f\u7528\u3092\u76ee\u7684\u3068\u3057\u3066\u3044\u307e\u305b\u3093\u3002<\/p>\n<\/footer>","protected":false},"excerpt":{"rendered":"<p>\u305d\u306e\u30d1\u30fc\u30bb\u30f3\u30c6\u30fc\u30b8\u304c\u4f55\u3092\u6e2c\u5b9a\u3057\u3066\u3044\u308b\u306e\u304b\u3092\u5b66\u3073\u3001\u6b21\u306b\u30d4\u30fc\u30af\u304c\u3069\u306e\u3088\u3046\u306b\u6570\u3048\u3089\u308c\u305f\u304b\u3092\u78ba\u8a8d\u3057\u307e\u3057\u3087\u3046\u3002<\/p>","protected":false},"author":0,"featured_media":0,"parent":865,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"footnotes":""},"class_list":["post-866","page","type-page","status-publish","hentry"],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v28.0 (Yoast SEO v28.1) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>HPLC Peptide Purity: Work Through a 98% Result | NHD<\/title>\n<meta name=\"description\" content=\"Learn what the percentage measures, then check how the peaks were counted.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/nhdbio.com\/ja\/\u5206\u6790\u624b\u6cd5\/hplc\u306b\u3088\u308b\u30da\u30d7\u30c1\u30c9\u306e\u7d14\u5ea6\/\" \/>\n<meta property=\"og:locale\" content=\"ja_JP\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"HPLC Peptide Purity: Work Through a 98% Result\" \/>\n<meta property=\"og:description\" content=\"Learn what the percentage measures, then check how the peaks were counted.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/nhdbio.com\/ja\/\u5206\u6790\u624b\u6cd5\/hplc\u306b\u3088\u308b\u30da\u30d7\u30c1\u30c9\u306e\u7d14\u5ea6\/\" \/>\n<meta property=\"og:site_name\" content=\"NHD\" \/>\n<meta property=\"article:modified_time\" content=\"2026-10-11T05:22:36+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/nhdbio.com\/wp-content\/plugins\/nhd-content-refresh\/guide-images\/866\/en\/1.png\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:description\" content=\"Peptide Raw Materials and Custom Peptide Synthesis\" \/>\n<meta name=\"twitter:label1\" content=\"\u63a8\u5b9a\u8aad\u307f\u53d6\u308a\u6642\u9593\" \/>\n\t<meta name=\"twitter:data1\" content=\"4\u5206\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/nhdbio.com\\\/analytical-methods\\\/hplc-peptide-purity\\\/\",\"url\":\"https:\\\/\\\/nhdbio.com\\\/analytical-methods\\\/hplc-peptide-purity\\\/\",\"name\":\"HPLC Peptide Purity: Work Through a 98% Result | NHD\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/nhdbio.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/nhdbio.com\\\/analytical-methods\\\/hplc-peptide-purity\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/nhdbio.com\\\/analytical-methods\\\/hplc-peptide-purity\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/nhdbio.com\\\/wp-content\\\/plugins\\\/nhd-content-refresh\\\/guide-images\\\/866\\\/en\\\/1.png\",\"datePublished\":\"2026-09-02T06:35:32+00:00\",\"dateModified\":\"2026-10-11T05:22:36+00:00\",\"description\":\"Learn what the percentage measures, then check how the peaks were counted.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/nhdbio.com\\\/analytical-methods\\\/hplc-peptide-purity\\\/#breadcrumb\"},\"inLanguage\":\"ja\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/nhdbio.com\\\/analytical-methods\\\/hplc-peptide-purity\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"ja\",\"@id\":\"https:\\\/\\\/nhdbio.com\\\/analytical-methods\\\/hplc-peptide-purity\\\/#primaryimage\",\"url\":\"https:\\\/\\\/nhdbio.com\\\/wp-content\\\/plugins\\\/nhd-content-refresh\\\/guide-images\\\/866\\\/en\\\/1.png\",\"contentUrl\":\"https:\\\/\\\/nhdbio.com\\\/wp-content\\\/plugins\\\/nhd-content-refresh\\\/guide-images\\\/866\\\/en\\\/1.png\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/nhdbio.com\\\/analytical-methods\\\/hplc-peptide-purity\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/nhdbio.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Analytical Methods &#038; COA Knowledge Center\",\"item\":\"https:\\\/\\\/nhdbio.com\\\/analytical-methods\\\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"HPLC Peptide Purity: Work Through a 98% Result\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/nhdbio.com\\\/#website\",\"url\":\"https:\\\/\\\/nhdbio.com\\\/\",\"name\":\"NHD\",\"description\":\"Peptide Raw Materials and Custom Peptide Synthesis\",\"publisher\":{\"@id\":\"https:\\\/\\\/nhdbio.com\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/nhdbio.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"ja\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/nhdbio.com\\\/#organization\",\"name\":\"NHD\",\"url\":\"https:\\\/\\\/nhdbio.com\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"ja\",\"@id\":\"https:\\\/\\\/nhdbio.com\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/nhdbio.com\\\/wp-content\\\/uploads\\\/2026\\\/09\\\/codex-clipboard-354c928e-4b5b-482d-9261-02023d4c9680.png\",\"contentUrl\":\"https:\\\/\\\/nhdbio.com\\\/wp-content\\\/uploads\\\/2026\\\/09\\\/codex-clipboard-354c928e-4b5b-482d-9261-02023d4c9680.png\",\"width\":2172,\"height\":724,\"caption\":\"NHD\"},\"image\":{\"@id\":\"https:\\\/\\\/nhdbio.com\\\/#\\\/schema\\\/logo\\\/image\\\/\"}}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"HPLC \u30da\u30d7\u30c1\u30c9\u7d14\u5ea6: 98% \u306e\u7d50\u679c\u3092\u7406\u89e3\u3059\u308b | NHD","description":"\u305d\u306e\u30d1\u30fc\u30bb\u30f3\u30c6\u30fc\u30b8\u304c\u4f55\u3092\u6e2c\u5b9a\u3057\u3066\u3044\u308b\u306e\u304b\u3092\u5b66\u3073\u3001\u6b21\u306b\u30d4\u30fc\u30af\u304c\u3069\u306e\u3088\u3046\u306b\u6570\u3048\u3089\u308c\u305f\u304b\u3092\u78ba\u8a8d\u3057\u307e\u3057\u3087\u3046\u3002","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/nhdbio.com\/ja\/\u5206\u6790\u624b\u6cd5\/hplc\u306b\u3088\u308b\u30da\u30d7\u30c1\u30c9\u306e\u7d14\u5ea6\/","og_locale":"ja_JP","og_type":"article","og_title":"HPLC Peptide Purity: Work Through a 98% Result","og_description":"Learn what the percentage measures, then check how the peaks were counted.","og_url":"https:\/\/nhdbio.com\/ja\/\u5206\u6790\u624b\u6cd5\/hplc\u306b\u3088\u308b\u30da\u30d7\u30c1\u30c9\u306e\u7d14\u5ea6\/","og_site_name":"NHD","article_modified_time":"2026-10-11T05:22:36+00:00","og_image":[{"url":"https:\/\/nhdbio.com\/wp-content\/plugins\/nhd-content-refresh\/guide-images\/866\/en\/1.png","type":"","width":"","height":""}],"twitter_card":"summary_large_image","twitter_description":"Peptide Raw Materials and Custom Peptide Synthesis","twitter_misc":{"\u63a8\u5b9a\u8aad\u307f\u53d6\u308a\u6642\u9593":"4\u5206"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/nhdbio.com\/analytical-methods\/hplc-peptide-purity\/","url":"https:\/\/nhdbio.com\/analytical-methods\/hplc-peptide-purity\/","name":"HPLC \u30da\u30d7\u30c1\u30c9\u7d14\u5ea6: 98% \u306e\u7d50\u679c\u3092\u7406\u89e3\u3059\u308b | NHD","isPartOf":{"@id":"https:\/\/nhdbio.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/nhdbio.com\/analytical-methods\/hplc-peptide-purity\/#primaryimage"},"image":{"@id":"https:\/\/nhdbio.com\/analytical-methods\/hplc-peptide-purity\/#primaryimage"},"thumbnailUrl":"https:\/\/nhdbio.com\/wp-content\/plugins\/nhd-content-refresh\/guide-images\/866\/en\/1.png","datePublished":"2026-09-02T06:35:32+00:00","dateModified":"2026-10-11T05:22:36+00:00","description":"\u305d\u306e\u30d1\u30fc\u30bb\u30f3\u30c6\u30fc\u30b8\u304c\u4f55\u3092\u6e2c\u5b9a\u3057\u3066\u3044\u308b\u306e\u304b\u3092\u5b66\u3073\u3001\u6b21\u306b\u30d4\u30fc\u30af\u304c\u3069\u306e\u3088\u3046\u306b\u6570\u3048\u3089\u308c\u305f\u304b\u3092\u78ba\u8a8d\u3057\u307e\u3057\u3087\u3046\u3002","breadcrumb":{"@id":"https:\/\/nhdbio.com\/analytical-methods\/hplc-peptide-purity\/#breadcrumb"},"inLanguage":"ja","potentialAction":[{"@type":"ReadAction","target":["https:\/\/nhdbio.com\/analytical-methods\/hplc-peptide-purity\/"]}]},{"@type":"ImageObject","inLanguage":"ja","@id":"https:\/\/nhdbio.com\/analytical-methods\/hplc-peptide-purity\/#primaryimage","url":"https:\/\/nhdbio.com\/wp-content\/plugins\/nhd-content-refresh\/guide-images\/866\/en\/1.png","contentUrl":"https:\/\/nhdbio.com\/wp-content\/plugins\/nhd-content-refresh\/guide-images\/866\/en\/1.png"},{"@type":"BreadcrumbList","@id":"https:\/\/nhdbio.com\/analytical-methods\/hplc-peptide-purity\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/nhdbio.com\/"},{"@type":"ListItem","position":2,"name":"Analytical Methods &#038; COA Knowledge Center","item":"https:\/\/nhdbio.com\/analytical-methods\/"},{"@type":"ListItem","position":3,"name":"HPLC Peptide Purity: Work Through a 98% Result"}]},{"@type":"WebSite","@id":"https:\/\/nhdbio.com\/#website","url":"https:\/\/nhdbio.com\/","name":"NHD","description":"\u30da\u30d7\u30c1\u30c9\u539f\u6599\u30fb\u30ab\u30b9\u30bf\u30e0\u30da\u30d7\u30c1\u30c9\u5408\u6210","publisher":{"@id":"https:\/\/nhdbio.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/nhdbio.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"ja"},{"@type":"Organization","@id":"https:\/\/nhdbio.com\/#organization","name":"NHD","url":"https:\/\/nhdbio.com\/","logo":{"@type":"ImageObject","inLanguage":"ja","@id":"https:\/\/nhdbio.com\/#\/schema\/logo\/image\/","url":"https:\/\/nhdbio.com\/wp-content\/uploads\/2026\/09\/codex-clipboard-354c928e-4b5b-482d-9261-02023d4c9680.png","contentUrl":"https:\/\/nhdbio.com\/wp-content\/uploads\/2026\/09\/codex-clipboard-354c928e-4b5b-482d-9261-02023d4c9680.png","width":2172,"height":724,"caption":"NHD"},"image":{"@id":"https:\/\/nhdbio.com\/#\/schema\/logo\/image\/"}}]}},"_links":{"self":[{"href":"https:\/\/nhdbio.com\/ja\/wp-json\/wp\/v2\/pages\/866","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/nhdbio.com\/ja\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/nhdbio.com\/ja\/wp-json\/wp\/v2\/types\/page"}],"replies":[{"embeddable":true,"href":"https:\/\/nhdbio.com\/ja\/wp-json\/wp\/v2\/comments?post=866"}],"version-history":[{"count":5,"href":"https:\/\/nhdbio.com\/ja\/wp-json\/wp\/v2\/pages\/866\/revisions"}],"predecessor-version":[{"id":4046,"href":"https:\/\/nhdbio.com\/ja\/wp-json\/wp\/v2\/pages\/866\/revisions\/4046"}],"up":[{"embeddable":true,"href":"https:\/\/nhdbio.com\/ja\/wp-json\/wp\/v2\/pages\/865"}],"wp:attachment":[{"href":"https:\/\/nhdbio.com\/ja\/wp-json\/wp\/v2\/media?parent=866"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}