One HPLC Peak Can Hide Two Components: Learn to Read Separation
Learn why peak shape matters before you read a purity percentage.
A chromatogram has one large peak. Does that mean the sample contains only one component? Not necessarily. Two components arriving close together can produce a signal that looks like one peak. Here is how that happens.
First, what does a peak show?
In HPLC, a sample passes through a column. Different components may travel through it at different speeds. The detector records their signals as they leave: time runs along the horizontal axis, and signal strength along the vertical axis.
When two components leave almost together, the detector may record a combined shape rather than two clearly separate peaks.

Why a better separation changes the picture
Imagine two groups walking through a doorway. If they arrive together, you may count them as one crowd. If they arrive at different times, the groups are easier to tell apart. Separation in the column serves a similar purpose.
In the second teaching plot, the two peaks are farther apart. That makes each easier to inspect and measure. These are simulated curves, not a before-and-after test of an NHD batch.

Use a number to describe how far apart the peaks are
Resolution, written Rs, compares the gap between two peak times with their widths. For this example, use widths measured at the baseline: Rs = 2 × (second time − first time) ÷ (first width + second width).
The peaks occur at 5.0 and 5.6 minutes, with baseline widths of 0.4 minutes each. Rs = 2 × 0.6 ÷ 0.8 = 1.5. A wider gap or narrower peaks gives a larger value.
Do not mix baseline widths with half-height widths; they use different formulas. Also, 1.5 is this example’s answer, not an acceptance rule for every method.
Why this matters for purity
An area-based purity calculation depends on which signals the method separates, detects and counts. If another component hides under the target peak, its signal may be included in that area.
So read the whole chromatogram and the method, not just the percentage. Peak shape alone cannot tell you the identity of every component either.

Try a closer pair of peaks
Keep both baseline widths at 0.4 minutes, but move the second peak to 5.2 minutes. The gap is now only 0.2 minutes.
See the answer
2 × 0.2 ÷ 0.8 = 0.5. The smaller value reflects a smaller gap relative to peak width.